SPECIFICATION

Pressure
Adjustment range 3..150 PSI (bar and MPa available)
Average differential 2..15 PSI (bar and MPa available)
Accuracy ±2% of full set point range at 21°C
Repeatability ±2% of full set point range at 21°C  Ambient Temperature
Temperature range Buna-N:-15°..230°F(-26°..110°C)
EPDM: -10°..250°F (-23°..121°C)
KAPTON®: -40°..230°F(-40°..110°C)
VITON®: 0°..250°F(-18°..121°C)
Low temp Nitrile: -40°..230°F(-40°..110°C)
Maximum overpressure 350 PSI (24 Bar)
Electrical Standard: 5A, 125V/250VAC – U.L. Recognized*
Option – 7: 0.2A,60VDC - U.L. Recognized* | 5A,12/24VDC - U.L. Recognized*
Switch type Snap Action
Protection Exposed terminal – IP00
DIN HC – IP65 | Flying leads, M12, Deutsch Integral – IP69
Wetted material Diaphragm: Buna-N (standard) | (Optional EPDM, KAPTON®, VITON®)
Housing: Brass | (Optional Steel – Electroless Nickel Plated Steel) | (Optional 316 Stainless Steel)
Mechanical life 1,000,000 cycles
Weight 0.15 LBS(0.07 kg)